HONEYWELL / Honeywell XCD Oxygen Gas Tester Alarm SPXCDALMO1
1
  • HONEYWELL / Honeywell XCD Oxygen Gas Tester Alarm SPXCDALMO1
2
views: 217

HONEYWELL / Honeywell XCD Oxygen Gas Tester Alarm SPXCDALMO1

Rate:
0.0000/5

( 0 reviews )

Item NO.: V001188 MOQ: 0
Weight:    3kgs
Package Size:  
 Price:
$0.00
 Qty:
      $0.00
 Shipping:   Calculate Shipping Cost

ZZC


Sensepoint XCD transducer
make use of The 3-line, 4-20mA, universal transmitter is suitable for catalytic combustion, electrochemistry and NDIR sensing, used for gas detection in internal and external combustible and toxic environments.
Electrical parameters Input voltage: STD, RFD: 16-32Vdc (rated: 24Vdc).RTD; 18-32Vdc (rated: 24Vd)
power dissipation: Electrochemical: 3.7W, infrared: 3.7W, catalytic combustion 4.9w
Current output: 4-20mA {source or leaky type)
≥0.0<1.0 mA hitch
4.0 mA- 20.0 mA Standard gas detection
2.0 mA or 4.0 mA (17.4 mA) Suphibit output when setting parameters or calibration)
22.0 mA outrange
binding post STD: 15 terminals: RTD & RFD: 1 daily terminals,
Through diameter 0.5mm(2oAWG)-2.5rmm (134WG)
electric relay Three 5A 25OVAC capacity relays, set normally open or closed and incentive or non-incentive
communication RS485 Modbus
structure
Transmitter material Aluminum alloy, 316 stainless steel
Sensor material 316 Stainless steel
weight Aluminum alloy: 2.4kg.316 stainless steel: 4.5kg
way to install Wall wall or pipe installation
connect Two M20 (or 2x3 / 4 " NPT) field incoming line interfaces.One M25 sensor connector
function
repetitiveness ‘+1-1%full range
degree of linearity /1%full range
accuracy + 15% full range (O2, CO, H2S, catalytic combustion}
response time T50≤15sT90≤30s(Catalytic combustion and infrared sensors)
Measured gas


attestation
China GB Ex d llC T4GB3836.1&2-2000,PA,CCCF
Korea KTL Exd II C T6(-40°℃ to +65°C)
America UL-Class I,Division 1,Groups B,C and D,Class I, Division 2,Groups B,C&D.
Class ll.Division, Groups E,F& G.Class ll,Division 2,Groups F& G.-40°℃ to+65C
Canada cUL/CSA
Europe ATEX EX II2 GDEx d llc Gb T6(Ta-40℃ to +65"C)Ex tb IIIC T85℃ Db IP66
international IEC Ex d llc Gb T6(Ta -40℃ to+65C)Ex tb IIIC T85C Db lP66
ship classification society ABS,MED,CCS
EMC EN50270:2006 EN6100-6-4 2007
environment
IP levels of protection lP66 (as per EN60529:1992)
working temperature ﹣40°C to +65°C
Working humidity Continuous work 20-90%RH (non-condensing), intermittent work 10-99%RH (non-condensing)
working pressure 90-110kPa
Storage conditions ﹣25°C to*65°C(-13°F to*149°F)

 
No comment