Inverter FC100
1
  • Inverter FC100
2
views: 197

Inverter FC100

Rate:
0.0000/5

( 0 reviews )

Item NO.: V000022 MOQ: 0
Weight:    0kgs
Package Size:  
 Price:
$0.00
 Qty:
      $0.00
 Shipping:   Calculate Shipping Cost

HC

Inverter FC100

delivery time:





Power range
      200-240 V ..... 1.1 kW - 45 kW
      380-480V.....1.1kW-1000kW
      525-600 V ..... 1.1 kW - 90 kW
      525-690 V ..... 45 kW - 1,2 MW


Appendix
      IP20/chassis, IP21/NEMA 1, IP55/NEMA 12 and IP66/NEMA 4X


For HVAC
      PI controller parameter self-tuning with special characteristics Equipped with a PI controller with self-tuning function, the inverter controller observes the response of the controlled system to its correction, and then the PI controller performs self-learning, corrects parameters, and outputs control signals so that the system can quickly enter stable and precise operation.


Automatic energy optimization
      As a standard feature, Automatic Energy Optimization (AEO) allows the motor to achieve the ideal magnetization at all speeds and loads. This improves energy efficiency by 5-15% under partial load.


energy monitoring
      The VLT HVAC Drive provides comprehensive energy consumption information, allowing the identification of inefficient components of the HVAC system.


Automatic resonance monitoring
      The frequency bands that cause the connected fans to resonate in the ventilation system can be avoided by simply setting the frequency converter. This helps reduce installation time and system wear.


Fan belt monitoring
      The VLT HVAC Drive provides comprehensive energy consumption information, allowing the identification of inefficient components of the HVAC system.


Fire Override Mode
      In Fire Override Mode, the VLT® HVAC Drive will ignore control signals, warnings or alarms. In order to ensure that people can evacuate safely in a smoke-free environment, it will operate reliably for as long as possible until it destroys itself.


Fan belt monitoring
      The VLT HVAC Drive can reliably determine a broken belt from the relationship between current and speed.




Fire Override Mode
      In Fire Override Mode, the VLT® HVAC Drive will ignore control signals, warnings or alarms. In order to ensure that people can evacuate safely in a smoke-free environment, it will operate reliably for as long as possible until it destroys itself.


temperature set point
      Without the need for additional software, sensors or controllers, the VLT® HVAC Drive can calculate the actual room temperature from the pressure of the cooling medium and then adjust the compressor operation accordingly. This makes it possible to use less expensive pressure sensors.


Pipe Fill Mode
      Pipe filling becomes a controllable process (closed loop). It can eliminate water hammer, burst pipes and water-air mixing in pipes.


End of working curve function detects pipeline ruptures and leaks
      This function can detect pipeline rupture and leakage. When the pump runs at the end of the working curve, it will trigger the inverter to issue an alarm, stop the pump or execute other actions preset by the user.


Dry pump protection reduces maintenance costs
      The VLT HVAC Drive continuously evaluates pump operation based on internal frequency/power measurements.


Standard Cascade Controller
      The built-in cascade controller can control up to three pumps.


Motor rotation
      The built-in logic control function can realize the rotation between two pumps in one use and one standby. The activation of a backup pump prevents the pumps from rusting, while a built-in timer ensures that each pump operates at approximately the same level of wear and tear.


Flow compensation
      The flow compensation feature reduces the pressure set point based on flow, resulting in significant energy savings.


Start/stop speed step
      The starting speed step can quickly accelerate the pump to the minimum value of the normal working speed range, avoiding the damage of bearings and mechanical seals caused by the pump running at low speed for a long time. Sensorless pressure and flow control


 


safety
      The VLT HVAC Drive has the optional Safe Stop feature and meets the requirements for Category 3 installations in EN 954-1. This function prevents the drive from starting unexpectedly.


Appendix


      When using the VLT HVAC Drive, you can choose from a variety of accessories to suit your needs. For details, please refer to the operating instructions


Options
      Various options for bus communication, user settings, etc. are plug-and-play.


Display options
      Local Control Panel LCP (graphical and digital) LCP cable, 3 m Local Control Panel (LCP) Remote Mount Kit


Application options
      External 24 V power supply card


Fieldbus options
      PROFIBUS DP V1 (MCA 101) Profisafe-Stop (MCA 103)
      DeviceNet (MCA 104)
      CAN Open Loop (MCA 105)
      Ethernet IP (MCA 121)


I/O options
      General Purpose I/O (MCB 101) Relay Option Card (MCB 105)
      External 24V DC power supply option (MCB-107)
      Analog I/O and Real Time Clock Battery Backup (MCB-109).


filter
      Harmonic Filter (AHF 005/010 MCE)
      Sine wave filter (MCC 101)
      dU/dt filter (MCC 102)


Other options
IP21/NEMA1 Kit
      USB cable to connect to PC
      Harmonic Filter AHF005/10

 
No comment
Total 0 records, divided into1 pages. First Prev Next Last
View History
Related tools
$9424.80
$506.50
$2737.40
$1942.00
$26.60
$1972.50
Business time
9:00-22:00
  • Email:zorx@xaplc.com