ZLL
XPSLCMUT1160
delivery time:8-12 weeks
MAIN | |
---|---|
Range of product | Telemecanique Safety light curtains XUSL |
Product or component type | Preventa safety module |
Safety module name | XPSLCM |
Safety module application | For the muting function of type 2 and type 4 safety light curtains monitored |
Function of module | Muting |
Safety level |
Can reach PL = e with the appropriate control system and correctly wired conforming to EN/ISO 13849-1 Can reach category 4 with the appropriate control system and correctly wired conforming to EN/ISO 13849-1 Can reach SILCL 3 with the appropriate control system and correctly wired conforming to EN/IEC 62061 |
Safety reliability data |
PFHd = 6.42E-9...5.03E-8 1/h conforming to EN/IEC 62061 B10d = 800000 conforming to EN/ISO 13849-1 MTTFd = 26...100 years conforming to EN/ISO 13849-1 DC = 96.2...98.9 % conforming to EN/ISO 13849-1 |
Synchronisation time between inputs | 4 s of muting |
Connections - terminals | Screw terminal |
Output type | 2 relay, 2 A at 24 V |
Number of additional circuits |
1 solid state PNP (NO), 100 mA for status on 24 V 1 solid state PNP (NO), 20.8…208 mA for lamp on 24 V |
[Us] rated supply voltage | 24 V DC - 20...20 % |