MHH
LRS-200-24
delivery time:in stock
Features |
AC input range selectable by switch |
Withstand 300VAC surge input for 5 second |
Protections: Short circuit/ Overload 1 Over voltage 1 Over temperature |
Cooling by free air convection |
1U low profile |
Withstand 5G vibration test |
LED indicator for power on |
No load power consumption<0.75W |
100% full load burn-in test |
High operating temperature up to 70°C |
Operating altitude up to 5000 meters (Note.8) |
High eficiency, long life and high relability |
ENVRONMENT | WORKING TEMP. | -25~+70℃(Refer to "Derating Curve") |
wORKING HUMIDITY | 20~90% RH non-condensing | |
STORAGE TEMP.,HUMIDITY | -40~+85℃,10~95% RH | |
TEMP.COEFFICIENT | ±0.03%/c(0~50℃) | |
VIBRATION | 10~500Hz,5G 10minJ1cycle,60min.each alongx,Y,Zaxes | |
SAFETY | SAFETYSTANDARDS |
IEC/UL62368-1,BSMI CNS14336-1,EACTPTCO04,KC K60950-1(for LRS-200-12/24 only), BISIS13252(Part1):2010/IEC 60950-1:2005,ASINZS62368.1 approved;Design refer to BSEN/EN62368-1 |
WITHSTAND VOLTAGE | IP-O/P:3KVAc WP-FG:2KVAc O/P-FG:0.5KVAc | |
ISOLATION RESISTANCE | uP-O/P,UP-FG,O/P-FG:100M Ohms / 500VDc/25℃/70%RH | |
EMCEMISSION | Compliance to BSMIl CNS13438,EAC TPTC 020,KC KN32,KN35(forLRS-200-12/24 only) | |
EMCIMMUNITY | Compliance toEAC TPTC 020,KC KN32,KN35(for LRS-200-12/24 only) | |
OTHERS | MTBF | 2346.6K hrs min. Telcordia SR-332(Bellcore); 279.4Khrs min.MIL-HDBK-217F(25C) |
DIMENSION | 215*115*30mm(LWH) | |
PACKING | 0.66Kg;15pcs/10.9Kgl0.78CUFT |