MHH
750-333
delivery time:in stock
Communication | PROFIBUS |
Number of fieldbus nodes on master (max.) | 96 |
Number of I/O points | 6,000 |
Baud rate | 9.6 kBd … 12 MBd |
Bus segment length (max.) | 1200 m |
Transmission medium | Cu cable per EN 50170 |
Transmission time | typ. 1 ms (10 couplers; each 32 digital I/O and 12 Mbaud) max. 3.3 ms |
Number of modules per node (max.) | 63 |
Input and output process image (fieldbus) max. | 244 bytes/244 bytes |
Supply voltage (system) | 24 VDC (-25 … +30 %); via pluggable connector (CAGE CLAMP® connection) |
Current consumption (5 V system supply) | 200mA |
Total current (system supply) | 1,800mA |
Supply voltage (field) | 24 VDC (-25 … +30 %); via power jumper contacts |
Input current (typ.) at nominal load (24 V) | 500mA |
Power supply efficiency (typ.) at nominal load (24 V) | 87% |
Isolation | 500 V system/field |
Number of outgoing power jumper contacts | 3 |
Current carrying capacity (power jumper contacts) | 10A |
Standard | EN 50170 |
Connection technology: communication/fieldbus | PROFIBUS: 1 x D-Sub 9 socket |
Connection technology: field supply | 6 x CAGE CLAMP® |
Connection technology: system supply | 2 x CAGE CLAMP® |
Connection technology: device configuration | 1 x Male connector; 4-pole |
Connection type 1 | System/field supply |
Solid conductor | 0.08 … 2.5 mm² / 28 … 14 AWG |
Fine-stranded conductor | 0.08 … 2.5 mm² / 28 … 14 AWG |
Strip length | 8 … 9 mm / 0.31 … 0.35 inches |
Width | 50.5 mm / 1.988 inches |
Height | 100 mm / 3.937 inches |
Depth | 71.1 mm / 2.799 inches |
Depth from upper-edge of DIN-rail | 63.9 mm / 2.516 inches |
Mounting type | DIN-35 rail |
Color | light gray |
Housing material | Polycarbonate; polyamide 6.6 |
Fire load | 2.988MJ |
Weight | 183.1g |
Conformity marking | CE |
Ambient temperature (operation) | 0 … +55 °C |
Surrounding air temperature (storage) | -25 … +85 °C |
Protection type | IP20 |
Pollution degree (5) | 2 per IEC 61131-2 |
Operating altitude | 0 … 2000 m / 0 … 6562 ft |
Mounting position | horizontal (standing/lying); vertical |
Relative humidity (without condensation) | 95% |
Vibration resistance | 4g per IEC 60068-2-6 |
Shock resistance | 15g per IEC 60068-2-27 |
EMC immunity to interference | per EN 61000-6-2, marine applications |
EMC emission of interference | per EN 61000-6-4, marine applications |
Exposure to pollutants | Per IEC 60068-2-42 and IEC 60068-2-43 |
Permissible H2S contaminant concentration at a relative humidity |
10ppm |
Permissible SO2 contaminant concentration at a relative humidity |
25ppm |