LC1D80G7
1
  • LC1D80G7
  • LC1D80G7
  • LC1D80G7
  • LC1D80G7
  • LC1D80G7
2
views: 306

LC1D80G7

Rate:
0.0000/5

( 0 reviews )

Item NO.: V006572 MOQ: 0
Weight:    2kgs
Package Size:  
 Price:
$264.67
 Qty:
      $264.67
 Shipping:   Calculate Shipping Cost

HC

LC1D80G7

Delivery time: 8-10 weeks







range TeSys
product name TeSys D
TeSys Deca
Product or Component Type Contactor
device short name LC1D
contactor application Motor control
Resistive load
utilisation category AC-1
AC-4
AC-3
AC-3e
poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage Power circuit <= 300 V DC 25...400 Hz
Power circuit <= 690 V AC
[Ie] rated operational current 125 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
80 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
80 A 140 °F (60 °C)) <= 440 V AC-3e power circuit
motor power kW 22 kW 220...230 V AC 50/60 Hz AC-3)
37 kW 380...400 V AC 50/60 Hz AC-3)
45 kW 415...440 V AC 50/60 Hz AC-3)
55 kW 500 V AC 50/60 Hz AC-3)
45 kW 660...690 V AC 50/60 Hz AC-3)
45 kW 1000 V AC 50/60 Hz AC-3)
15 kW 400 V AC 50/60 Hz AC-4)
motor power HP (UL / CSA) 7.5 hp 120 V at AC 50/60 Hz for 1 phase
15 hp 230/240 V at AC 50/60 Hz for 1 phase
30 hp 200/208 V at AC 50/60 Hz for 3 phase
30 hp 230/240 V at AC 50/60 Hz for 3 phase
60 hp 460/480 V at AC 50/60 Hz for 3 phase
60 hp 575/600 V at AC 50/60 Hz for 3 phase
control circuit type AC 50/60 Hz
[Uc] control circuit voltage 120 V AC 50/60 Hz
auxiliary contact composition 1 NO + 1 NC
[Uimp] rated impulse withstand voltage 8 kV IEC 60947
overvoltage category III
[Ith] conventional free air thermal current 10 A 140 °F (60 °C) signalling circuit
125 A 140 °F (60 °C) power circuit
Irms rated making capacity 140 A AC signalling circuit IEC 60947-5-1
250 A DC signalling circuit IEC 60947-5-1
1100 A 440 V power circuit IEC 60947
rated breaking capacity 1100 A 440 V power circuit IEC 60947
[Icw] rated short-time withstand current 640 A 104 °F (40 °C) - 10 s power circuit
990 A 104 °F (40 °C) - 1 s power circuit
135 A 104 °F (40 °C) - 10 min power circuit
320 A 104 °F (40 °C) - 1 min power circuit
100 A - 1 s signalling circuit
120 A - 500 ms signalling circuit
140 A - 100 ms signalling circuit
associated fuse rating 10 A gG signalling circuit IEC 60947-5-1
200 A gG <= 690 V type 1 power circuit
160 A gG <= 690 V type 2 power circuit
average impedance 0.8 mOhm - Ith 125 A 50 Hz power circuit
[Ui] rated insulation voltage Power circuit 600 V CSA
Power circuit 600 V UL
Power circuit 1000 V IEC 60947-4-1
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
electrical durability 0.8 Mcycles 125 A AC-1 <= 440 V
1.5 Mcycles 80 A AC-3 <= 440 V
1.5 Mcycles 80 A AC-3e <= 440 V
power dissipation per pole 5.1 W AC-3
12.5 W AC-1
5.1 W AC-3e
Front cover With
Mounting Support Rail
Plate
standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
Product Certifications DNV
GL
UL
CCC
LROS (Lloyds register of shipping)
RINA
BV
GOST
CSA
connections - terminals Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end
Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)flexible with cable end
Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable end
Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable end
Power circuit connector 1 0.01…0.08 in² (4…50 mm²)flexible without cable end
Power circuit connector 2 0.01…0.04 in² (4…25 mm²)flexible without cable end
Power circuit connector 1 0.01…0.08 in² (4…50 mm²)flexible with cable end
Power circuit connector 2 0.01…0.02 in² (4…16 mm²)flexible with cable end
Power circuit connector 1 0.01…0.08 in² (4…50 mm²)solid without cable end
Power circuit connector 2 0.01…0.04 in² (4…25 mm²)solid without cable end
tightening torque Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2
Power circuit 106.21 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm
Power circuit 106.21 lbf.in (12 N.m) connector hexagonal 0.16 in (4 mm)
Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2
operating time 20...35 ms closing
6...20 ms opening
safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
mechanical durability 4 Mcycles
maximum operating rate 3600 cyc/h 140 °F (60 °C)
Complementary
coil technology Without built-in suppressor module
control circuit voltage limits 0.85...1.1 Uc -40…131 °F (-40…55 °C) operational AC 60 Hz
0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz
0.8...1.1 Uc -40…131 °F (-40…55 °C) operational AC 50 Hz
1...1.1 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz
inrush power in VA 245 VA 60 Hz 0.75 68 °F (20 °C))
245 VA 50 Hz 0.75 68 °F (20 °C))
hold-in power consumption in VA 26 VA 60 Hz 0.3 68 °F (20 °C))
26 VA 50 Hz 0.3 68 °F (20 °C))
heat dissipation 6…10 W 50/60 Hz
auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
signalling circuit frequency 25...400 Hz
minimum switching current 5 mA signalling circuit
minimum switching voltage 17 V signalling circuit
non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
insulation resistance > 10 MOhm signalling circuit

 
No comment