ZLL
ATV61HD11N4
delivery time:in stock
range of product
Altivar 61
product or component type
Variable speed drive
product specific application
Pumping and ventilation machine
component name
ATV61
motor power kW
11 kW, 3 phases at 380...480 V
motor power hp
15 hp, 3 phases at 380...480 V
power supply voltage
380...480 V - 15...10 %
supply number of phases
3 phases
line current
30 A for 480 V 3 phases 11 kW / 15 hp
36.6 A for 380 V 3 phases 11 kW / 15 hp
EMC filter
Level 3 EMC filter
assembly style
With heat sink
apparent power
24.1 kVA at 380 V 3 phases 11 kW / 15 hp
maximum prospective line Isc
22 kA for 3 phases
maximum transient current
33.2 A for 60 s, 3 phases
nominal switching frequency
12 kHz
switching frequency
1...16 kHz adjustable
12...16 kHz with derating factor
asynchronous motor control
Voltage/frequency ratio, 2 points
Flux vector control without sensor, standard
Voltage/frequency ratio, 5 points
Voltage/frequency ratio - Energy Saving, quadratic U/f
synchronous motor control profile
Vector control without sensor, standard
communication port protocol
Modbus
CANopen
type of polarization
No impedance for Modbus
option card
Communication card for APOGEE FLN
Communication card for BACnet
Communication card for CC-Link
Controller inside programmable card
Communication card for DeviceNet
Communication card for EtherNet/IP
Communication card for Fipio
I/O extension card
Communication card for Interbus-S
Communication card for LonWorks
Communication card for METASYS N2
Communication card for Modbus Plus
Communication card for Modbus TCP
Communication card for Modbus/Uni-Telway
Multi-pump card
Communication card for Profibus DP
Communication card for Profibus DP V1
product destination
Synchronous motors
Asynchronous motors
power supply voltage limits
323…528 V
power supply frequency
50...60 Hz - 5...5 %
power supply frequency limits
47.5...63 Hz
continuous output current
21 A at 12 kHz, 460 V - 3 phases
27.7 A at 12 kHz, 380 V - 3 phases
output frequency
0.1…599 Hz
speed range
1…100 in open-loop mode, without speed feedback
speed accuracy
+/- 10 % of nominal slip 0.2 Tn to Tn without speed feedback
torque accuracy
+/- 15 % in open-loop mode, without speed feedback
transient overtorque
130 % of nominal motor torque +/- 10 % for 60 s
braking torque
<= 125 % with braking resistor
30 % without braking resistor
regulation loop
Frequency PI regulator
motor slip compensation
Automatic whatever the load
Can be suppressed
Not available in voltage/frequency ratio (2 or 5 points)
Adjustable
diagnostic
1 LED (red) for drive voltage
output voltage
<= power supply voltage
electrical isolation
Between power and control terminals
type of cable for mounting in an enclosure
With an IP21 or an IP31 kit: 3 wire(s)IEC cable at 40 °C, copper 70 °C / PVC
With UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC
Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC
Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR
electrical connection
Terminal 2.5 mm² / AWG 14 (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)
Terminal 16 mm² / AWG 4 (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)
tightening torque
0.6 N.m (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)
3 N.m, 26.5 lb.in (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)
supply
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC, +/- 5 %, <10 mA with overload and short-circuit protection
Internal supply: 24 V DC (21…27 V), <200 mA with overload and short-circuit protection
External supply: 24 V DC (19…30 V)
analogue input number
2
analogue input type
AI1-/Al1+ bipolar differential voltage: +/- 10 V DC 24 V max, resolution 11 bits + sign
AI2 software-configurable current: 0...20 mA, impedance: 242 Ohm, resolution 11 bits
AI2 software-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 11 bits
sampling time
2 ms +/- 0.5 ms (AI1-/Al1+) - analog input
2 ms +/- 0.5 ms (Al2) - analog input
2 ms +/- 0.5 ms (AO1) - analog output
2 ms +/- 0.5 ms (LI1...LI5) - discrete input
2 ms +/- 0.5 ms (LI6)if configured as logic input - discrete input
absolute accuracy precision
+/- 0.6 % (AI1-/Al1+) for a temperature variation 60 °C
+/- 0.6 % (AI2) for a temperature variation 60 °C
+/- 1 % (AO1) for a temperature variation 60 °C
linearity error
+/- 0.15 % of maximum value (AI1-/Al1+)
+/- 0.15 % of maximum value (AI2)
+/- 0.2 % (AO1)
analogue output number
1
analogue output type
AO1 software-configurable current, analogue output range 0...20 mA, impedance: 500 Ohm, resolution 10 bits
AO1 software-configurable voltage, analogue output range 0...10 V DC, impedance: 470 Ohm, resolution 10 bits
AO1 software-configurable logic output 10 V, 20 mA
discrete output number
2
discrete output type
Configurable relay logic: (R1A, R1B, R1C) NO/NC - 100000 cycles
Configurable relay logic: (R2A, R2B) NO - 100000 cycles
maximum response time
<= 100 ms in STO (Safe Torque Off)
R1A, R1B, R1C <= 7 ms, tolerance +/- 0.5 ms
R2A, R2B <= 7 ms, tolerance +/- 0.5 ms
minimum switching current
3 mA at 24 V DC for configurable relay logic
maximum switching current
R1, R2: 2 A at 250 V AC inductive load, cos phi = 0.4 and L/R = 7 ms
R1, R2: 2 A at 30 V DC inductive load, cos phi = 0.4 and L/R = 7 ms
R1, R2: 5 A at 250 V AC resistive load, cos phi = 1 and L/R = 0 ms
R1, R2: 5 A at 30 V DC resistive load, cos phi = 1 and L/R = 0 ms
discrete input number
7
discrete input type
Programmable (LI1...LI5)24 V DC (<= 30 V), with level 1 PLC - 3500 Ohm
Switch-configurable (LI6)24 V DC (<= 30 V), with level 1 PLC - 3500 Ohm
Switch-configurable PTC probe (LI6)0…6 probes - 1500 Ohm
Safety input (PWR)24 V DC (<= 30 V) - 1500 Ohm
discrete input logic
Negative logic (sink) (LI1...LI5), > 16 V (state 0), < 10 V (state 1)
Positive logic (source) (LI1...LI5), < 5 V (state 0), > 11 V (state 1)
Negative logic (sink) (LI6)if configured as logic input, > 16 V (state 0), < 10 V (state 1)
Positive logic (source) (LI6)if configured as logic input, < 5 V (state 0), > 11 V (state 1)
acceleration and deceleration ramps
Linear adjustable separately from 0.01 to 9000 s
S, U or customized
Automatic adaptation of ramp if braking capacity exceeded, by using resistor
braking to standstill
By DC injection
protection type
Against exceeding limit speed: drive
Against input phase loss: drive
Break on the control circuit: drive
Input phase breaks: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Overcurrent between output phases and earth: drive
Overheating protection: drive
Overvoltages on the DC bus: drive
Power removal: drive
Short-circuit between motor phases: drive
Thermal protection: drive
Motor phase break: motor
Power removal: motor
Thermal protection: motor
insulation resistance
> 1 mOhm 500 V DC for 1 minute to earth
frequency resolution
Analog input: 0.024/50 Hz
Display unit: 0.1 Hz
connector type
1 RJ45 (on front face) for Modbus
1 RJ45 (on terminal) for Modbus
Male SUB-D 9 on RJ45 for CANopen
physical interface
2-wire RS 485 for Modbus
transmission frame
RTU for Modbus
transmission rate
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal
9600 bps, 19200 bps for Modbus on front face
20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen
data format
8 bits, 1 stop, even parity for Modbus on front face
8 bits, odd even or no configurable parity for Modbus on terminal
number of addresses
1…127 for CANopen
1…247 for Modbus
method of access
Slave CANopen
marking
CE
operating position
Vertical +/- 10 degree
net weight
7 kg
width
210 mm
height
295 mm
depth
213 mm