ZLL
GF711S
delivery time:in stock
Product characteristics
Electrical design
PNP
Output function
2 x OSSD (A1 and A2)
Enable zone [mm]
0.5...4
Housing
Threaded type
Dimensions [mm]
M12 x 1 / L = 70
Application
System
gold-plated contacts
Type of operation
continuous operation (maintenance-free)
Safety-related function
safe state when undamped
Application
Industrial applications
Electrical data
Operating voltage [V]
19.2...30 DC
Rated insulation voltage [V]
30
Current consumption [mA]
< 20
Protection class
III
Reverse polarity protection
yes
Max. power-on delay time [ms]
1000
Outputs
Electrical design
PNP
Output function
2 x OSSD (A1 and A2)
Max. voltage drop switching output DC [V]
2.5; (30 mA)
Permanent current rating of switching output DC [mA]
100
Output data
Interface type C class 1
Output voltage at 24 V
compatible with EN 61131-2 inputs type 1, 2
Short-circuit protection
yes
Overload protection
no
Max. capacitive load CL_max [nF]
20
Monitoring range
Enable zone [mm]
0.5...4
Safe switching-off distance s(ar) [mm]
6
Reaction times
Response time to safety request [ms]
1
Response time when approaching the enable zone [ms]
1
Risk time (response time for safety-related faults) [ms]
20
Operating conditions
Applications
Class C to EN 60654-1 weatherproof application
Ambient temperature [°C]
-25...70
Note on ambient temperature
Ambient temperature [°C]
10...40
Note on ambient temperature
Rate of temperature change [K/min]
0.5
Max. relative air humidity [%]
briefly: 5...95 %; permanent: 5...70 %
Air pressure [kPa]
80...106
Max. height above sea level [m]
2000
Ionizing radiation
not permissible
Salt spray
no
Protection
IP 65; IP 67