LC1-D18M7C
1
  • LC1-D18M7C
  • LC1-D18M7C
2
views: 168

LC1-D18M7C

Rate:
0.0000/5

( 0 reviews )

Item NO.: V007542 MOQ: 0
Weight:    1kgs
Package Size:  
 Price:
$11.50
 Qty:
      $11.50
 Shipping:   Calculate Shipping Cost

HCM

LC1-D18M7C

Delivery time:in stock


Short product name


LC1D


Contactor application field


Applied to non inductive or micro inductive load and resistance furnace


Applied to AC load with power factor greater than or equal to 0.95


Use Category


AC-4


AC-1


AC-3


AC-3e


Number of poles


3P


Rated operating voltage [Ue]


Power circuit:<=690 V AC 25... 400 Hz


Power circuit:<=225 V DC


Rated working current [Ie]


32 A 60 ° C) on...<=440 V AC AC-1 for power circuit


18 A 60 ° C) on...<=440 V AC AC-3 for power circuit


18 A 60 ° C) on...<=440 V AC AC-3e for power circuit


[Uc] control circuit voltage


230V AC 50/60 Hz


Supplementary information


Motor power (kW)


10 kW at 500 V AC 50/60 Hz (AC-3)


4 kW on 220/240 V AC 50/60 Hz (AC-3)


7.5 kW on... 380/400 V AC 50/60 Hz (AC-3)


9 kW on 415/440 V AC 50/60 Hz (AC-3)


10 kW on 660/690 V AC 50/60 Hz (AC-3)


4 kW on 400 V AC 50/60 Hz (AC-4)


10 kW at 500 V AC 50/60 Hz (AC-3e)


4 kW on 220/240 V AC 50/60 Hz (AC-3e)


7.5 kW on... 380/400 V AC 50/60 Hz (AC-3e)


9 kW on 415/440 V AC 50/60 Hz (AC-3e)


10 kW on 660/690 V AC 50/60 Hz (AC-3e)


model


LC1D


Loop contact type


3 NO


Protective cover


nothing


Agreed heating current [Ith]


10 A signal loop for<60 ° C on


32 A<60 ° C on


Rated short-time withstand current [Icw]


145 A<40 ° C on... - 10 s for power circuit


240 A at<40 ° C - 1 s for power circuit


40 A at<40 ° C - 10 minutes for power circuit


84 A<40 ° C on - 1 minute for power circuit


100 A - 1 s applicable signal loop


120 A - 500 ms applicable signal loop


140 A - 100 ms applicable signal loop


Fuses for use with relays


10 A gG applicable signal circuit complies with IEC 60947-5-1


50 A gG on


35 A gG on


Average impedance


2.5 m Ω - Ith 32 A 50 Hz applicable power circuit


Rated insulation voltage [Ui]


Power circuit: 690 V in accordance with IEC 60947-4-1


Signal circuit: 690 V in accordance with IEC 60947-1


Overvoltage category


III


class of pollution


three


Rated impulse withstand voltage [Uimp]


6 kV acc. to IEC 60947


Safety and reliability level


B10d=1369863 contactors with nominal load according to EN/ISO 13849-1


B10d=20000000 mechanical load contactors in accordance with EN/ISO 13849-1


Mechanical life


15 Mcycles


Electrical life


1 Mcycles<=440 V at 32 A AC-1 Ue


1.6<=440 V at Mcycles 18 A AC-3 Ue


660/690 V at 3 Mcycles 11 A AC-3 Ue


1.6<=440 V at Mcycles 18 A AC-3e Ue


660/690 V at 3 Mcycles 11 A AC-3e Ue


Control loop characteristics


AC 50/60 Hz on


Surge suppression module


No built-in surge suppression module


Control voltage limit


0.3... 0.6 Uc - 40... 60 ° C release 50/60 Hz


0.8... 1.1 Uc - 40... 60 ° C operation 50 Hz


0.85... 1.1 Uc - 40... 60 ° C operation 60 Hz


(~50Hz pull in) Power consumption (VA)


70 VA 60 Hz 0.75 20 °C)


70 VA 50 Hz 0.75 20 °C)


(~50Hz holding) Power consumption (VA)


7.5 VA 60 Hz 0.3 20 °C)


7 VA 50 Hz 0.3 20 °C)


Heat dissipation


2... 3 W at 50/60 Hz


Action time


12... 22 ms closed


4... 19 ms breaking


Maximum operating frequency


3600 times/hour<60 ° C on


Wiring capacity


Control circuit: bolt fastening 1 1... 4 mm ² Cable selection: flexible cable without cable terminal


Control circuit: bolt fastening 2 1... 4 mm ² Cable selection: flexible cable without cable terminal


Control circuit: bolt fastening 1 1... 4 mm ² Cable selection: flexible cable with crimp terminal


Control circuit: bolt fastening 2 1... 2.5 mm ² Cable selection: flexible cable with crimp terminal


Control circuit: bolt fastening 1 1... 4 mm ² Cable selection: hard wire without cable terminal


Control circuit: bolt fastening 2 1... 4 mm ² Cable selection: hard wire without cable terminal


Power circuit: bolt fastening 1.5... 6 mm ² Outer diameter of lug Ø: 8 mm Cable type selection: flexible wire without cable terminal


Power circuit: bolt fastening 2 1.5... 6 mm ² Outer diameter of lug Ø: 8 mm Cable type selection: flexible wire without cable terminal


Power circuit: bolt fastening 1 1... 6 mm ² Outer diameter of lug Ø: 8 mm Cable selection: flexible cord with crimp terminal


Power circuit: bolt fastening 2 1... 4 mm ² Outer diameter of lug Ø: 8 mm Cable selection: flexible cord with crimp terminal


Power circuit: bolt fastening 1.5... 6 mm ² Outer diameter of lug Ø: 8 mm Cable selection: hard wire terminal without hoop wire


Power circuit: bolt fastening 2 1.5... 6 mm ² Outer diameter of lug Ø: 8 mm Cable selection: hard wire terminal without hoop wire


Tightening torque


Power circuit: 1.7 N.m, screw driver ØØØØØØØØØØØØØØØ216


Power circuit: 1.7 N.m screw driver No 2 cross screw for fastening by bolts


Control circuit: 1.7 N.m, screw driver ØØØØØØØØØØØØØØØ216


Control circuit: 1.7 N.m screw driver No 2 cross screw for fastening by bolts


Power circuit: 1.7 N.m Screw driver Ø 6 through cable connector Flat screw: M3.5


Power circuit: 1.7 N.m Screwdriver for cable connector No 2 Phillips screw: M3.5


Power circuit: 1.7 N.m screwdriver pozidriv No 2 for bolt fastening


Control circuit: 1.7 N.m screwdriver pozidriv No 2 for bolt fastening


Auxiliary contact type


1 NO + 1 NC


Auxiliary contact type


Type Mechanical connection 1 NO+1 NC acc. to IEC 60947-5-1


Type is mirror image of main contact state 1 NC conforms to IEC 60947-4-1


Signal loop frequency


25...400 Hz


Minimum switching voltage


17 V applicable signal circuit


Minimum switching current [Imin]


5 mA applicable signal loop


insulation resistance


>10 M Ω applicable signal circuit


No overlapping time


Between NC and NO contacts after 1.5 ms power loss


Between NC and NO contacts energized for 1.5 ms


Installation method


DIN-Rail Mounting


Base plate installation


environment


standard


GB 14048.4


IEC 60947-4-1


Product certification


CCC


CE


UKCA


IP protection class


IP2x front panel main circuit is applicable to IEC 60529


IP2x front panel coil circuit is applicable to IEC 60529


Protective measures


TH according to IEC 60068-2-30


Ambient air temperature


-40... 60 ° C operation


60... 70 ° C with derating


-60... 80 ° C storage


Operating altitude


3000 m None


Fire resistance and abnormal high temperature resistance


850 ° C according to IEC 60695-2-11


Impact and vibration resistance


Seismic performance Contact opening (2 gn (5... 300 Hz)) in accordance with IEC 60068-2-6


Seismic performance Contact closing state (4 gn (5... 300 Hz)) in accordance with IEC 60068-2-6


Impact resistance 11 ms contact opening (10 gn) in accordance with IEC 60068-2-27


Impact resistance 11 ms contact closing state (15 gn) in accordance with IEC 60,068-2-27


height


77 mm


width


45 mm


depth


86 mm

 