RD0-TIEX8.FF.ST
1
  • RD0-TIEX8.FF.ST
  • RD0-TIEX8.FF.ST
  • RD0-TIEX8.FF.ST
  • RD0-TIEX8.FF.ST
  • RD0-TIEX8.FF.ST
2
views: 168

RD0-TIEX8.FF.ST

Rate:
0.0000/5

( 0 reviews )

Item NO.: V007612 MOQ: 0
Weight:    1kgs
Package Size:  
 Price:
$5078.90
 Qty:
      $5078.90
 Shipping:   Calculate Shipping Cost

HCM

RD0-TIEX8.FF.ST

Delivery time:10-12 weeks


  • For T/C, RTD 2-, 3-, 4-wire, voltage and resistance

  • Cold junction compensation

  • Removable terminals

  • General specifications

  • Design / Mounting : Cabinet installation

  • Fieldbus interface

  • Fieldbus type : FOUNDATION Fieldbus

  • Physical layer profile : profile type 511 (FISCO), profile type 111 (Entity)

  • ITK version : 4.51

  • Implementation : resource block1x RS
    function block8x AI, 1x MAI
    transducer block8x sensor TB, 1x concentrator TB

  • Execution time : AI, MAI 40 ms max.

  • Macro cycle : typical for one device 8xAI or 1xMAI max. 500 ms

  • Firmware update : via separate plug connection

  • FDE (Fault Disconnect Equipment) : 6.7 mA

  • Polarity : not polarity sensitive

  • Rated voltage : 9 ... 32 V

  • Rated current : max. 23 mA

  • Indicators/operating means

  • LED PWR : green: on, bus voltage existent

  • LED COM ERR : red: continuous lightning: hardware error; 2 Hz flashing: no bus activities or bus fault; off: no error

  • LED CHANNEL ERROR : red: 2 Hz flashing: lead breakage, overrange; off: no error

  • Input Number : 8

  • Sensor types : see table 1

  • Grounding : grounding of thermoelements possible

  • Error detection : lead breakage, wiring error, hardware device error

  • Common mode voltage : Input to Input 600 Vpeak

  • Transfer characteristics

  • Deviation

  • Influence of ambient temperature : see table 3

  • Linearization : T/C input 0.1°C RTD input 0.03°C

  • Internal measurement cycle : for all sensor types max. 1 s

  • Galvanic isolation

  • Fieldbus/inputs : safe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V

  • Directive conformity

  • Electromagnetic compatibility

  • Directive 2014/30/EU : EN 61326-1:2013

  • Standard conformity

  • Galvanic isolation : EN 60079-11

  • Electromagnetic compatibility : NE 21:2011

  • Degree of protection : IEC 60529

  • Fieldbus standard : IEC 61158-2

  • Shock resistance : EN 60068-2-27

  • Vibration resistance : EN 60068-2-6

  • Ambient conditions

  • Ambient temperature : -40 ... 70 °C (-40 ... 158 °F) hazardous area 
    -40 ... 85 °C (-40 ... 185 °F) safe area

  • Storage temperature : -40 ... 85 °C (-40 ... 185 °F)

  • Relative humidity : = 95 % non-condensing

  • Shock resistance : 15 g , 11 ms

  • Vibration resistance : 5 g , 10 ... 150 Hz

  • Corrosion resistance : acc. to ISA-S71.04-1985, severity level G3

  • Mechanical specifications

  • Connection type : plug-in terminals , spring terminal and screw terminal

  • Core cross-section

  • Bus : up to 2.5 mm2

  • Inputs : up to 2.5 mm2

  • Housing material : Polycarbonate

 