LC1D50M7C
1
  • LC1D50M7C
2
views: 213

LC1D50M7C

Rate:
0.0000/5

( 0 reviews )

Item NO.: V008203 MOQ: 0
Weight:    1kgs
Package Size:  
 Price:
$35.50
 Qty:
      $35.50
 Shipping:   Calculate Shipping Cost

HCM

LC1D50M7C

Delivery time:in stock


Main information


Product range


TeSys Deca


Product range


TeSys Deca


product type


Contactor


Short product name


LC1D


Contactor application field


Applied to AC load with power factor greater than or equal to 0.95


Applied to non inductive or micro inductive load and resistance furnace


Use Category


AC-4


AC-1


AC-3


AC-3e


Number of poles


3P


Rated operating voltage [Ue]


Power circuit:<=690 V AC 25... 400 Hz


Power circuit:<=300 V DC


Rated working current [Ie]


50 A 60 ° C) on...<=440 V AC AC-3 for power circuit


80 A 60 ° C) on...<=440 V AC AC-1 for power circuit


50 A 60 ° C) on...<=440 V AC AC-3e for power circuit


[Uc] control circuit voltage


230V AC 50/60 Hz


Supplementary information


Motor power (kW)


30 kW at 500 V AC 50/60 Hz (AC-3)


25 kW on 415 V AC 50/60 Hz (AC-3)


30 kW on 440 V AC 50/60 Hz (AC-3)


15 kW on 220/240 V AC 50/60 Hz (AC-3)


22 kW on... 380/400 V AC 50/60 Hz (AC-3)


33 kW on 660/690 V AC 50/60 Hz (AC-3)


11 kW on 400 V AC 50/60 Hz (AC-4)


30 kW at 500 V AC 50/60 Hz (AC-3e)


25 kW on 415 V AC 50/60 Hz (AC-3e)


30 kW on 440 V AC 50/60 Hz (AC-3e)


15 kW on 220/240 V AC 50/60 Hz (AC-3e)


22 kW on... 380/400 V AC 50/60 Hz (AC-3e)


33 kW on 660/690 V AC 50/60 Hz (AC-3e)


model


LC1D


Loop contact type


3 NO


Protective cover


nothing


Agreed heating current [Ith]


10 A signal loop for<60 ° C on


80 A<60 ° C on


Rated short-time withstand current [Icw]


400 A at<40 ° C - 10 s for power circuit


810 A<40 ° C on... - 1 s for power circuit


84 A<40 ° C on - 10 minutes for power circuit


208 A<40 ° C on... - 1 minute for power circuit


100 A - 1 s applicable signal loop


120 A - 500 ms applicable signal loop


140 A - 100 ms applicable signal loop


Fuses for use with relays


10 A gG applicable signal circuit complies with IEC 60947-5-1


100 A gG on


100 A gG on<=690 V with type 2 applicable power circuit


Average impedance


1.5 m Ω - Ith 80 A 50 Hz applicable power circuit


Rated insulation voltage [Ui]


Signal circuit: 690 V in accordance with IEC 60947-1


Power circuit: 1000 V in accordance with IEC 60947-4-1


Overvoltage category


III


class of pollution


three


Rated impulse withstand voltage [Uimp]


6 kV acc. to IEC 60,947


Safety and reliability level


B10d=1369863 contactors with nominal load according to EN/ISO 13849-1


B10d=20000000 mechanical load contactors in accordance with EN/ISO 13849-1


Mechanical life


6 Mcycles


Electrical life


1.2<=440 V at Mcycles 80 A AC-1 Ue


1.5 Mcycles<=440 V at 50 A AC-3 Ue


660/690 V at 2 Mcycles 35 A AC-3 Ue


1.5 Mcycles<=440 V at 50 A AC-3e Ue


2 660/690 V at Mcycles 35 A AC-3e Ue


Control loop characteristics


AC 50/60 Hz on


Surge suppression module


No built-in surge suppression module


Control voltage limit


0.3... 0.6 Uc - 40... 60 ° C release 50/60 Hz


0.8... 1.1 Uc - 40... 60 ° C operation 50 Hz


0.85... 1.1 Uc - 40... 60 ° C operation 60 Hz


(~50Hz pull in) Power consumption (VA)


245 VA 60 Hz 0.75 20 °C)


245 VA 50 Hz 0.75 20 °C)


(~50Hz holding) Power consumption (VA)


26 VA 60 Hz 0.3 20 °C)


26 VA 50 Hz 0.3 20 °C)


Heat dissipation


6... 10 W at 50/60 Hz


Action time


20... 26 ms closed


8... 12 ms breaking


Maximum operating frequency


3600 times/hour<60 ° C on


Wiring capacity


Control circuit: bolt fastening 1 1... 4 mm ² Cable selection: flexible cable without cable terminal


Control circuit: bolt fastening 2 1... 4 mm ² Cable selection: flexible cable without cable terminal


Control circuit: bolt fastening 2 1... 2.5 mm ² Cable selection: flexible cable with crimp terminal


Control circuit: bolt fastening 1 1... 4 mm ² Cable selection: hard wire without cable terminal


Control circuit: bolt fastening 2 1... 4 mm ² Cable selection: hard wire without cable terminal


Control circuit: bolt fastening 1 1... 2.5 mm ² Cable selection: flexible cable with crimp terminal


Power circuit: terminal 1 2.5... 25 mm ² Outer diameter of lug Ø: 13 mm Cable selection: flexible wire without crimp terminal


Power circuit: terminal 2 2.5... 16 mm ² Outer diameter of lug Ø: 13 mm Cable selection: flexible wire without crimp terminal


Power circuit: terminal 1 2.5... 25 mm ² Outer diameter of lug Ø: 13 mm Cable selection: flexible cord with crimp terminal


Power circuit: terminal 2 2.5... 10 mm ² Outer diameter of lug Ø: 13 mm Cable selection: flexible cord with crimp terminal


Power circuit: terminal 1 2.5... 25 mm ² Outer diameter of lug Ø: 13 mm Cable type selection: hard wire without cable terminal


Power circuit: terminal 2 2.5... 16 mm ² Outer diameter of lug Ø: 13 mm Cable type selection: hard wire without cable terminal


Tightening torque


Control circuit: 1.2 N.m, screw driver Ø 6, flat end for bolt fastening


Control circuit: 1.2 N.m screw driver No 2 cross screws for fastening by bolts


Power circuit: 5 N.m, screw driver for fastening by bolts; 6... 8 mm, slotted


Power circuit: 5 N.m Screwdriver Ø 8 through cable connector Slotted screw: M6


Power circuit: 5 N.m screwdriver for cable connector No 3 Phillips screw: M6


Power circuit: 5 N.m screwdriver pozidriv No 2 for bolt fastening


Control circuit: 1.2 N.m screwdriver pozidriv No 2 for bolt fastening


Auxiliary contact type


1 NO + 1 NC


Auxiliary contact type


Type Mechanical connection 1 NO+1 NC acc. to IEC 60947-5-1


Type is mirror image of main contact state 1 NC conforms to IEC 60947-4-1


Signal loop frequency


25...400 Hz


Minimum switching current [Imin]


5 mA applicable signal loop


insulation resistance


>10 M Ω applicable signal circuit


No overlapping time


Between NC and NO contacts after 1.5 ms power loss


Between NC and NO contacts energized for 1.5 ms


Installation method


Base plate installation


DIN-Rail Mounting


environment


standard


GB 14048.4


IEC 60947-4-1


Product certification


CCC


CE


UKCA


IP protection class


IP2x front panel main circuit is applicable to IEC 60529


Protective measures


TH according to IEC 60068-2-30


Ambient air temperature


-40... 60 ° C operation


60... 70 ° C with derating


-60... 80 ° C storage


Operating altitude


3000 m None


Fire resistance and abnormal high temperature resistance


850 ° C according to IEC 60,695-2-11


Impact and vibration resistance


Seismic performance Contact opening (2 gn (5... 300 Hz)) in accordance with IEC 60068-2-6


Impact resistance 11 ms contact opening (8 gn) in accordance with IEC 60068-2-27


Impact resistance 11 ms contact closing state (10 gn) in accordance with IEC 60068-2-27


Seismic performance Contact closing state (3 gn (5... 300 Hz)) in accordance with IEC 60068-2-6


height


127 mm


width


75 mm


depth


119 mm

 