delivery time:in stock
roduct classification
Solid State Relay for heater control
Operating rated voltage
12 to 24 VDC
Operating voltage range
9.6 to 30 VDC
Must operate voltage
9.6 VDC max.
Must release voltage
1 VDC min.
Isolation method
Phototriac
Rated load voltage
100 to 240 VAC 50/60 Hz
Load voltage range
75 to 264 VAC 50/60 Hz
Load current
0.5 A to 45 A at 25 ℃
Inrush current resistivity
440 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
Output ON voltage drop
1.6 V (RMS)
Leakage current
10 mA (at 200 VAC)
Ambient temperature
Operating: -30 to 80 ℃
Storage: -30 to 100 ℃
(with no icing or condensation)
Ambient humidity
Operating: 45 to 85%RH
(with no icing or condensation)
Operate time
1/2 cycle of load power source + 1 ms max.
Release time
1/2 cycle of load power source + 1 ms max.
Zero cross function
Equipped
Indicator
Input indicator (INPUT (Yellow): Operating)
Insulation resistance
100 MΩ (at 500 VDC)
Dielectric strength
2500 V 50/60 Hz 1 min
Vibration resistance
10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) (mounted on DIN track)
Shock resistance
294 m/s**2 (DIN Track mounting)
Terminal structure
Screw terminal
Mounting
Screw mounting / DIN track