LC1D25MD
1
  • LC1D25MD
  • LC1D25MD
  • LC1D25MD
  • LC1D25MD
  • LC1D25MD
2
views: 175

LC1D25MD

Rate:
0.0000/5

( 0 reviews )

Item NO.: V007466 MOQ: 0
Weight:    1kgs
Package Size:  
 Price:
$40.40
 Qty:
      $40.40
 Shipping:   Calculate Shipping Cost

HCM

LC1D25MD

Delivery time:8 weeks


Contactor application field


Applied to non inductive or micro inductive load and resistance furnace


Applied to AC load with power factor greater than or equal to 0.95


Use Category


AC-3


AC-4


AC-1


AC-3e


Number of poles


3P


Rated operating voltage [Ue]


Power circuit:<=690 V AC 25... 400 Hz


Power circuit:<=300 V DC


Rated working current [Ie]


25 A 60 ° C) on...<=440 V AC AC-3 for power circuit


40 A 60 ° C) on...<=440 V AC AC-1 for power circuit


25 A 60 ° C) on...<=440 V AC AC-3e for power circuit


[Uc] control circuit voltage


230V DC


Supplementary information


Motor power (kW)


5.5 kW on 220... 230 V AC 50/60 Hz (AC-3)


11 kW on 380... 400 V AC 50/60 Hz (AC-3)


11 kW on 415... 440 V AC 50/60 Hz (AC-3)


15 kW at 500 V AC 50/60 Hz (AC-3)


15 kW on 660... 690 V AC 50/60 Hz (AC-3)


5.5 kW on 400 V AC 50/60 Hz (AC-4)


5.5 kW on 220... 230 V AC 50/60 Hz (AC-3e)


11 kW on 380... 400 V AC 50/60 Hz (AC-3e)


11 kW on 415... 440 V AC 50/60 Hz (AC-3e)


15 kW at 500 V AC 50/60 Hz (AC-3e)


15 kW on 660... 690 V AC 50/60 Hz (AC-3e)


Motor power


3 hp on... 230/240 V AC 50/60 Hz for 1-phase motors


2 hp on... 115 V AC 50/60 Hz for 1-phase motors


7.5 hp on... 230/240 V AC 50/60 Hz for 3-phase motors


15 hp on... 460/480 V AC 50/60 Hz for 3-phase motors


20 hp on... 575/600 V AC 50/60 Hz for 3-phase motors


7.5 hp on... 200/208 V AC 50/60 Hz for 3-phase motors


model


LC1D


Loop contact type


3 NO


Contactor compatibility characteristics


M4


Protective cover


belt


Agreed heating current [Ith]


10 A signal loop for<60 ° C on


40 A<60 ° C on


Rated making capacity [Irms]


140 A AC applicable signal circuit complies with IEC 60947-5-1


250 A DC applicable signal loop in accordance with IEC 60947-5-1


450 A on... 440 V applicable power circuit in accordance with IEC 60947


Rated breaking capacity


450 A on... 440 V applicable power circuit in accordance with IEC 60947


Rated short-time withstand current [Icw]


240 A at<40 ° C - 10 s for power circuit


380 A<40 ° C on... - 1 s for power circuit


50 A<40 ° C on... - 10 minutes for power circuit


120 A<40 ° C on... - 1 minute for power circuit


100 A - 1 s applicable signal loop


120 A - 500 ms applicable signal loop


140 A - 100 ms applicable signal loop


Fuses for use with relays


10 A gG applicable signal circuit complies with IEC 60,947-5-1


63 A gG on


40 A gG on


Average impedance


2 m Ω - Ith 40 A 50 Hz applicable power circuit


Power consumption per pole


3.2 W AC-1


1.25 W AC-3


1.25 W AC-3e


Rated insulation voltage [Ui]


Power circuit: 690 V in accordance with IEC 60,947-4-1


Power circuit: 600 V CSA certification


Power circuit: 600 V UL certification


Signal circuit: 690 V in accordance with IEC 60947-1


Signal circuit: 600 V CSA certification


Signal circuit: 600 V UL certification


Overvoltage category


III


class of pollution


three


Rated impulse withstand voltage [Uimp]


6 kV acc. to IEC 60947


Safety and reliability level


B10d=1369863 contactors with nominal load according to EN/ISO 13849-1


B10d=20000000 mechanical load contactors in accordance with EN/ISO 13849-1


Mechanical life


30 Mcycles


Electrical life


1.65 Mcycles<=440 V at 25 A AC-3 Ue


1.4<=440 V at Mcycles 40 A AC-1 Ue


1.65 Mcycles<=440 V at 25 A AC-3e Ue


Control loop characteristics


DC standard


Surge suppression module


Built in bidirectional peak current limiting diode


Control voltage limit


0.1... 0.25 Uc - 40... 70 ° C to release DC


0.7... 1.25 Uc - 40... 60 ° C operation DC


1... 1.25 Uc 60... 70 ° C operation DC


Surge power (W)


5.4 W 20 °C)


Holding power consumption (W)


5.4 W 20 ° C above


Action time


53.55... 72.45 ms Closed


16... 24 ms breaking


Time constant


28 ms


Maximum operating frequency


3600 times/hour<60 ° C on


Wiring capacity


Control circuit: bolt fastening 1 1... 4 mm ² Cable selection: flexible cable without cable terminal


Control circuit: bolt fastening 2 1... 4 mm ² Cable selection: flexible cable without cable terminal


Control circuit: bolt fastening 1 1... 4 mm ² Cable selection: flexible cable with crimp terminal


Control circuit: bolt fastening 2 1... 2.5 mm ² Cable selection: flexible cable with crimp terminal


Control circuit: bolt fastening 1 1... 4 mm ² Cable selection: hard wire without cable terminal


Control circuit: bolt fastening 2 1... 4 mm ² Cable selection: hard wire without cable terminal


Power circuit: bolt fastening 1 2.5... 10 mm ² Cable selection: flexible cable without cable terminal


Power circuit: bolt fastening 2 2.5... 10 mm ² Cable selection: flexible cable without cable terminal


Power circuit: bolt fastening 1 1... 10 mm ² Cable selection: flexible cable with crimp terminal


Power circuit: bolt fastening 2 1.5... 6 mm ² Cable selection: flexible cable with crimp terminal


Power circuit: bolt fastening 1.5... 10 mm ² Cable selection: hard wire without cable terminal


Power circuit: bolt fastening 2 2.5... 10 mm ² Cable selection: hard wire without cable terminal


Tightening torque


Control circuit: 1.7 N.m, screw driver ØØØØØØØØØØØØØØØ216


Control circuit: 1.7 N.m screw driver No 2 cross screw for fastening by bolts


Power circuit: 2.5 N.m, screw driver ØØØØØØØ 6, flat end


Power circuit: 2.5 N.m screw driver No 2 cross screw for fastening by bolts


Control circuit: 1.7 N.m screwdriver pozidriv No 2 for bolt fastening


Power circuit: 2.5 N.m screwdriver pozidriv No 2 for bolt fastening


Auxiliary contact type


1 NO + 1 NC


Auxiliary contact type


Type Mechanical connection 1 NO+1 NC acc. to IEC 60947-5-1


Type is mirror image of main contact state 1 NC conforms to IEC 60947-4-1


Signal loop frequency


25...400 Hz


Minimum switching voltage


17 V applicable signal circuit


Minimum switching current [Imin]


5 mA applicable signal loop


insulation resistance


>10 M Ω applicable signal circuit


No overlapping time


Between NC and NO contacts after 1.5 ms power loss


Between NC and NO contacts energized for 1.5 ms


Installation method


DIN-Rail Mounting


Base plate installation


environment


standard


CSA C22.2 No 14


EN 60947-4-1


EN 60947-5-1


IEC 60947-4-1


IEC 60947-5-1


UL 508


IEC 60335-1


Product certification


CCC


UL


LROS (Lloyds register of shipping)


BV


GOST


CSA


DNV


GL


RINA


UKCA


IP protection class


IP20 front panel according to IEC 60529


Protective measures


TH according to IEC 60068-2-30


Climatic tolerance


IACS E10 compliant Exposure to hot flashes


Comply with IEC 60947-1 Annex Q category D when exposed to damp heat


Ambient air temperature


-40…60 °C


60... 70 ° C with derating


Operating altitude


0...3000 m


Fire resistance and abnormal high temperature resistance


850 ° C according to IEC 60695-2-1


Flame retardant


V1 compliant with UL 94


Impact and vibration resistance


Seismic performance Contact opening (2 gn (5... 300 Hz))


Seismic performance Contact closed state (4 gn (5... 300 Hz))


Impact resistance contact closed state (15 gn (11ms))


Impact resistance contact opening (8 gn (11ms))


height


85 mm


width


45 mm


depth


101 mm

 
No comment