ZLL(YL)
PN7293
delivery time:12weeks
Product characteristics | |
---|---|
Number of inputs and outputs | Number of digital outputs: 2 |
Measuring range | |
Process connection | threaded connection 1/4" NPT Internal thread |
Application | |
System | gold-plated contacts |
Measuring element | ceramic-capacitive pressure measuring cell |
Application | for industrial applications |
Media | liquids and gases |
Medium temperature [°C] | -25...80 |
Min. bursting pressure | |
Pressure rating | |
Type of pressure | relative pressure |
MAWP (for applications according to CRN) | |
Electrical data | |
Operating voltage [V] | 18...30 DC; (to SELV/PELV) |
Current consumption [mA] | < 35 |
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | < 0.3 |
Integrated watchdog | yes |
Inputs / outputs | |
Number of inputs and outputs | Number of digital outputs: 2 |
Outputs | |
Total number of outputs | 2 |
Output signal | switching signal; IO-Link; (configurable) |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / closed; (configurable) |
Max. voltage drop switching output DC [V] | 2.5 |
Permanent current rating of switching output DC [mA] | 150; (200 (...60 °C) 250 (...40 °C)) |
Switching frequency DC [Hz] | < 170 |
Short-circuit protection | yes |
Type of short-circuit protection | yes (non-latching) |
Overload protection | yes |
Measuring/setting range | |
Measuring range | |
Factory setting / CMPT = 2 | |
Set point SP | |
Reset point rP | |
Min. difference between SP and rP | |
In steps of | |
Status_B High Resolution / CMPT = 3 | |
Set point SP | |
Reset point rP | |
Min. difference between SP and rP | |
In steps of | |
Accuracy / deviations | |
Switch point accuracy [% of the span] | < ± 0,5 |
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis deviation [% of the span] | < ± 0,25 |
Long-term stability [% of the span] | < ± 0,05; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K] | < ± 0,2; (-0...80 °C) |
Temperature coefficient span [% of the span / 10 K] | < ± 0,2; (-0...80 °C) |
Reaction times | |
Response time [ms] | < 3 |
Delay time programmable dS, dr [s] | 0...50 |
Software / programming | |
Parameter setting options | hysteresis / window; normally open / closed; switching logic; switch-on/switch-off delay; Damping; Display unit |
Interfaces | |
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 |
SIO mode | yes |
Required master port class | A; (when pin 2 not connected: B) |
Supported DeviceIDs | |
Note | |
Factory setting / CMPT = 2 | |
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
Min. process cycle time [ms] | 2.3 |
IO-Link resolution pressure [bar] | 0.1 |
IO-Link resolution pressure [MPa] | 0.01 |
IO-Link process data (cyclical) | |
IO-Link functions (acyclical) | application specific tag |
Status_B High Resolution / CMPT = 3 | |
Profiles | Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) |
Min. process cycle time [ms] | 3 |
IO-Link resolution pressure [bar] | 0.01 |
IO-Link resolution pressure [MPa] | 0.001 |
IO-Link process data (cyclical) | |
IO-Link functions (acyclical) | application specific tag |
Operating conditions | |
Ambient temperature [°C] | -25...80 |
Storage temperature [°C] | -40...100 |
Protection | IP 65; IP 67 |
Tests / approvals | |
EMC | |
Shock resistance | |
Vibration resistance | |
MTTF [years] | 260 |
UL approval | |
Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |